NDYnet has provided consulting engineering
services on major IT and Communication Centre
projects constructed across the United Kingdom
and Europe. Key city locations, include:
In each case, the firm has the prepared design
briefs, detailed feasibility studies, design
documentation and carried out contract administration
through the construction phase.
We would welcome the opportunity to provide
further details on any of our projects.
LONDON
TRANSATLANTIC FIBRE OPTIC CABLE LANDING STATION,
BUDE
Situated on the southwest coast of England
in Cornwall, this 35,000 square foot Technology
Centre houses transmission and power supply
equipment for a trans-continental fibre link
between America and England. A 5,000V DC power
system for the transmission cable is derived
in boost stages from the 54V central low voltage
DC power plant and battery system for supply
of transmission equipment.
Services by NDYnet include: Building Automation,
DC Power, Electrical Services, Emergency Power,
High Voltage, UPS, Fire Protection, Mechanical
Services, Public Health, and Security .
[TOP]
200,000 square feet INTERNET PROTOCOL GATEWAY
& COLOCATION CENTRE, LONDON
This technology development stands as one of
Europe's largest Internet Gateway and Colocation
Centres, built for an international Internet
Carrier.
Originally a Gin factory, this site has been
redeveloped to house a global IP exchange together
with collocation web hosting services. The facility
measures 200,000 square feet - and comprises
140,000 square feet of technical space for IP
function. When completed it will serve as a
major IP hub between North America and Europe.
The engineering services designed by NDYnet
comprise a 11kV 19MVA power system with 100%
standby generator backup. Technical space is
cooled by a refrigeration plant of 13,000 kWR
and serviced by a 7,500 kVA UPS power system
plant designed to provide an unsurpassed level
of resilience.
Services rendered by NDYnet include: Building
Automation, DC Power, Electrical Services, UPS,
Emergency Power, High Voltage, Fire Protection,
Mechanical Services, Public Health, Security,
and Vertical Transportation.
[TOP]
FRANCE
INTERNET GATEWAY AND COLOCATION CENTRE, PARIS
NDYnet are servicing the engineering needs
of a US based international Internet Carrier
in Paris.
Services provided by NDYnet include a review
of existing IP facilities in need of modification
and expansion - including the development of
engineering strategies to achieve critical service
standards.
Feasibility studies have also been undertaken
on potential sites to confirm new build options
for expansion of intercity web-centric IP networks.
[TOP]
INTERNET FIBRE OPTIC REGENERATION CENTRE,
LILLE
NDYnet have completed concept and detailed
designs for the construction of internet fibre
optic regeneration facilities in Lille, France.
The site can cater for three adjacent buildings
of 5,000ft² and provide a scaleable technology
/ infrastructure solution for efficient and
reliable fibre optic transmission.
Engineering architecture allows sharing of
redundant plant capacity between each module,
reducing capital costs while maintaining the
"n+1" resilience policy.
[TOP]
BELGIUM
INTERNET GATEWAY AND COLOCATION CENTRE, BRUSSELS
A 56,000 square feet telecommunications gateway
designed for an international IP Carrier, serves
as a critical pan European node and offers significant
collocation web hosting services to the Brussels
IP market.
The engineering systems designed by NDYnet
include, 4MVA HV network, 16,000Amp DC Power
System, 1,500kVA UPS power plant, 4 MVA emergency
power generation, 5,000kWR chiller plant and
chilled water systems.
Services by NDYnet include: Building Automation,
DC Power, Electrical Services, Emergency Power,
High Voltage, UPS, Fire Protection, Mechanical
Services, Public Health, and Security .
[TOP]
HOLLAND
INTERNET PROTOCOL COLOCATION EXPANSION, AMSTERDAM
NDYnet have undertaken a design management
role on behalf of an international technology
client, to review detailed design documentation
proposed as part of an expansion plan for an
existing IP facility.
NDYnet have led design team reviews and have undertaken
detailed assessments of Mechanical and Electrical
design options for chiller plant, Uninterruptible
Power Systems, Emergency Power Generation, Switchgear
Selection, Protective and Technical Earthing.
[TOP]
GERMANY
INTERNET PROTOCOL
GATEWAY & COLOCATION CENTRE, DÜSSELDORF
Two adjoining buildings have been redeveloped
to accommodate the needs of a global Internet
carrier in a 70,000 square feet Gateway and
Colocation centre development.
Constructed over three distinct phases, the
services for the complex development have been
designed to allow a staged fitout catering for
varying occupancy densities and future success
based capital.
The process of integrating the engineering
services within existing building structures
set a number of key challenges for the design
team, and involved close liaison with the building
owner.
Electrical plant for this build are located
at ground level, as incoming high voltage power
supply, transformers, generators and electrical
distribution for the facility has been incorporated
within the first phase.
Services by NDYnet include: Building Automation,
DC Power, Electrical Services, Emergency Power,
High Voltage, UPS, Fire Protection, Mechanical
Services, Public Health, and Security .
[TOP]
INTERNET PROTOCOL GATEWAY & COLOCATION CENTRE,
MUNICH
A 60,000 feet square IP Centre provides Internet
host and collocation services to IT industries
seeking data centre grade rental space to house
computer servers and networking equipment.
The centre was developed by an US International
IP Carrier to service network needs and the
growing demand for IP rental space in Munich.
NDYnet were engaged as the specialist engineering
services consultants for the development.
Engineering systems designed by NDYnet cater
for staged load growth and incorporate provision
for the uninterrupted installation of future
major plant to service increases in load demand.
Modular provisions include: cast-resin transformers,
main electrical switchboards, emergency power
generation, UPS systems, general distribution,
DC power plant, chillers and environmental cooling
units.
Centre capacities can cater for an ultimate
demand of 6,000 kVA - offering users up to 75
watts/ft2 in technical areas.
Extensive plant commissioning and tests were
overseen by NDYnet, to ensure the client received
an integrated and proven services installation.
Services by NDYnet include: Building Automation,
DC Power, Electrical Services, Emergency Power,
UPS, High Voltage, Fire Protection, Mechanical
Services, Public Health and Security.
INTERNET PROTOCOL GATEWAY,
BERLIN
A 76,000 square feet Internet Gateway with
a base load power consumption of 7MVA of which
100% can be generated locally when required.
The project involved the integration of an existing
structure with external shear walls requiring
2000mm deep cast concrete cable walkways to
be constructed between the main building and
external generator plants.
Mechanical plant is installed in external plant
compounds to make use of seasonal free cooling.
Chilled water mains are buried in trenches running
alongside the building before rising to serve
technical areas in ring formations.
Services by NDYnet include: Building Automation,
DC Power, Electrical Services, Emergency Power,
UPS, High Voltage, Fire Protection, Mechanical
Services, Public Health and Security.
[TOP]
INTERNET PROTOCOL GATEWAY
& COLOCATION CENTRE, HAMBURG
Developed on a "brown field" site, this 82,000
square feet Internet Gateway and Colocation
centre provided an opportunity to design a facility
that clearly demonstrated a 'best practice space
efficiency' policy.
The final design has provided the client with
optimum use of both land and building resources.
Simplicity and order in design has promoted
ease of construction and the ongoing maintainability
of key systems.
The building consists of an efficient, low
aspect ratio "warehouse" area. Plant forming
the EPG, UPS and DC systems, as well as the
backbone of the low voltage distribution, is
contained on the ground floor alongside collocation
space. The upper level of the warehouse contains
a further 40,000 square feet of clear technical
space. Heat rejection plant is housed in a rooftop
compound, further reducing property costs. A
two level glass fronted annexe to the building
contains administration, local operation control
centre and other support functions.
Services by NDYnet include: Building Automation,
DC Power, Electrical Services, Emergency Power,
UPS, High Voltage, Fire Protection, Mechanical
Services, Public Health and Security.